TradeSelect CeaseFire™
The ultimate non-combustible weather-proofing and vapour management membraneClassified as Class 4 Vapour Permeable, the advanced hydrophobic infusion blocks liquid water and air movement while allowing water vapour diffusion through the wall structure. Trade Select™ CeaseFire™ also contributes to a well-sealed building for maximum energy efficiency.
The E-Glass weave provides an Extra Heavy Duty and is not deemed combustible.
Product Advantages
- Non-combustible
- Class 4 Vapour Permeable
- Ember-proof and suitable for all BAL zones
- Water and Air Barrier
- High strength and puncture resistant
- Chemically inert / long life components
Applications
Trade Select™ CeaseFire™ is suitable for all NCC building classes in commercial and single or multi-storey residential fire resisting external wall constructions in regions of Australia south of the Tropic of Capricorn (ABCB Climate Zones 2-8), where both condensation management (NCC 2019 Vol. One F6.2) and non-combustible construction (NCC 2019 Vol. One C1.9 and Vol 2, C3.7.1.1) are required.
For ABCB Climate Zone 1 and north of the Tropic of Capricorn in climate zone 2, substitute with FireSark™ Vapour Barrier sarking and wall wrap.
Blank one so all stay closed
Product Details
Product Name | Trade Select™ CeaseFire™ |
Roll Size | 1500 mm x 30 m (45m2) |
Duty Rating | Extra Heavy |
R Values
Declared Total System R-Values | Winter | Summer |
Residential Roof 22° Pitch with Trade Select™ CeaseFire™, unventilated | RT0.57 | RT0.74 |
Profile Metal Cladding Fixed to battens with Trade Select™ CeaseFire™ + R2.7 fibrous batt | RT2.82 | RT2.68 |
Product Testing
Material Properties and Classifications
Trade Select CeaseFire® classifications in accordance with AS/NZS 4200.1:2017 and NCC 2019 Volume 1, C1.9 and NCC 2019 Volume 2, Part 3.7.4.1.
Combustibility | AS 1530.1-1994 | Not deemed combustible |
Flammability Index | AS 1530.2-1993 | Low (1) |
Early Fire Hazard Indicies | AS 1530.3-1993 | 0, 0, 0, 2 |
Fire Hazard Assessment | AS 5637.1:2015 | Group 1 |
Nominal Thickness | 0.17 mm | |
Duty Rating | AS/NZS 4200.1:2017 | Extra Heavy |
Vapour Control | ASTM E96 | Class 4 Vapour Permeable |
Vapour Permeance | ASTM E96 | 1.5767 μg/N.s |
Water Control | AS/NZS 4201.4:1994 | Water Barrier |
Air Control | ISO 6536/5-2003 | Air Barrier |
Resistance to Dry Delamination | AS/NZS 4201.1:1994 | Pass |
Resistance to Wet Delamination | AS/NZS 4201.2:1994 | Pass |
Shrinkage (Repeated wetting & drying) | AS/NZS 4201.3:1994 | 0.0% |
Emmitance | AS/NZS 4201.5:1994 | Grey side: 0.90, Printed side: 0.90 |
Combustibility
Not deemed combustible
E-glass tested in accordance with AS 1530.1-1994 Methods for fire tests on building materials, components and structures Part 1: Combustibility test for materials.
Fire Hazard Properties
Group 1
Classified in accordance with AS 5637.1:2015 Determination of fire hazard properties based on testing in accordance with AS/NZS 3837:1998 Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter.
Ignitability
Ignitability: 0, Spread of flame: 0, Heat evolved: 0, Smoke developed: 2
Tested in accordance with AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke release.
Flammability index
Low (1)
Tested in accordance with AS1530.2-1993 Methods for fire tests on building materials, components and structures Part 2: Test for flammability of materials.
Bushfire Attack Levels
Complies with AS 3959-2018 Construction of buildings in bushfire-prone areas for use in all BAL zone building constructions.
Seek independent advice regarding the selection of pliable building membranes prior to installation in the BAL design.
Specification Notes
Product Name: Trade Select™ CeaseFire™
The pliable building membrane to be installed shall be Trade Select™ CeaseFire™, tested in accordance with AS 1530.1-1994 Methods for fire tests on building materials, components and structures Part 1: Combustibility test for materials to satisfy NCC 2019, Vol 1, C1.9 for non-combustible constructions and shall be installed in accordance with AS 4200.2:2017 Pliable Building Membranes and Underlays, Part 2: Installation.
Combustibility: Not deemed combustible
Flammability Classification: Low (1)
Fire Hazard Properties: Group 1
Early Fire Hazard Indices: 0, 0, 0, 2
Vapour Control Classification: Class 4 Vapour Permeable, 1.5767 μg/N•s
Air Control Classification: Air Barrier
Water Control Classification: Water Barrier
Duty Classification: Extra Heavy in accordance with AS/NZS 4200.1:2017