TradeSelect CeaseFire™

The ultimate non-combustible weather-proofing and vapour management membrane
Trade Select™ CeaseFire™ is an advanced vapour permeable wall and roof membrane designed specifically as a non-combustible pliable building membrane for use in Type A and B fire resisting constructions and in all construction types where superior passive fire performance and vapour permeability is a priority.

Classified as Class 4 Vapour Permeable, the advanced hydrophobic infusion blocks liquid water and air movement while allowing water vapour diffusion through the wall structure. Trade Select™ CeaseFire™ also contributes to a well-sealed building for maximum energy efficiency.

The E-Glass weave provides an Extra Heavy Duty and is not deemed combustible.

Product Advantages

  • Non-combustible
  • Class 4 Vapour Permeable
  • Ember-proof and suitable for all BAL zones
  • Water and Air Barrier
  • High strength and puncture resistant
  • Chemically inert / long life components

Applications

Trade Select™ CeaseFire™ is suitable for all NCC building classes in commercial and single or multi-storey residential fire resisting external wall constructions in regions of Australia south of the Tropic of Capricorn (ABCB Climate Zones 2-8), where both condensation management (NCC 2019 Vol. One F6.2) and non-combustible construction (NCC 2019 Vol. One C1.9 and Vol 2, C3.7.1.1) are required.

For ABCB Climate Zone 1 and north of the Tropic of Capricorn in climate zone 2, substitute with FireSark™ Vapour Barrier sarking and wall wrap.

Blank one so all stay closed
Product Details
Product NameTrade Select™ CeaseFire™
Roll Size1500 mm x 30 m (45m2)
Duty RatingExtra Heavy
R Values
Declared Total System R-ValuesWinterSummer
Residential Roof
22° Pitch with Trade Select™ CeaseFire™, unventilated
RT0.57RT0.74
Profile Metal Cladding
Fixed to battens with Trade Select™ CeaseFire™ + R2.7 fibrous batt
RT2.82RT2.68
Product Testing

Material Properties and Classifications
Trade Select CeaseFire® classifications in accordance with AS/NZS 4200.1:2017 and NCC 2019 Volume 1, C1.9 and NCC 2019 Volume 2, Part 3.7.4.1.

 

CombustibilityAS 1530.1-1994Not deemed combustible
Flammability IndexAS 1530.2-1993Low (1)
Early Fire Hazard IndiciesAS 1530.3-19930, 0, 0, 2
Fire Hazard AssessmentAS 5637.1:2015Group 1
Nominal Thickness0.17 mm
Duty RatingAS/NZS 4200.1:2017Extra Heavy
Vapour ControlASTM E96Class 4 Vapour Permeable
Vapour PermeanceASTM E961.5767 μg/N.s
Water ControlAS/NZS 4201.4:1994Water Barrier
Air ControlISO 6536/5-2003Air Barrier
Resistance to Dry DelaminationAS/NZS 4201.1:1994Pass
Resistance to Wet DelaminationAS/NZS 4201.2:1994Pass
Shrinkage (Repeated wetting & drying)AS/NZS 4201.3:19940.0%
EmmitanceAS/NZS 4201.5:1994Grey side: 0.90, Printed side: 0.90
Fire Performance

Combustibility
Not deemed combustible

E-glass tested in accordance with AS 1530.1-1994 Methods for fire tests on building materials, components and structures Part 1: Combustibility test for materials.

Fire Hazard Properties
Group 1

Classified in accordance with AS 5637.1:2015 Determination of fire hazard properties based on testing in accordance with AS/NZS 3837:1998 Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter.

Ignitability
Ignitability: 0, Spread of flame: 0, Heat evolved: 0, Smoke developed: 2

Tested in accordance with AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke release.

Flammability index
Low (1)

Tested in accordance with AS1530.2-1993 Methods for fire tests on building materials, components and structures Part 2: Test for flammability of materials.

Bushfire Attack Levels
Complies with AS 3959-2018 Construction of buildings in bushfire-prone areas for use in all BAL zone building constructions.
Seek independent advice regarding the selection of pliable building membranes prior to installation in the BAL design.

Specification Notes
When specifying, state the following:


Product Name: Trade Select™ CeaseFire™

The pliable building membrane to be installed shall be Trade Select™ CeaseFire™, tested in accordance with AS 1530.1-1994 Methods for fire tests on building materials, components and structures Part 1: Combustibility test for materials to satisfy NCC 2019, Vol 1, C1.9 for non-combustible constructions and shall be installed in accordance with AS 4200.2:2017 Pliable Building Membranes and Underlays, Part 2: Installation.

Combustibility: Not deemed combustible
Flammability Classification: Low (1)
Fire Hazard Properties: Group 1
Early Fire Hazard Indices: 0, 0, 0, 2
Vapour Control Classification: Class 4 Vapour Permeable, 1.5767 μg/N•s
Air Control Classification: Air Barrier
Water Control Classification: Water Barrier
Duty Classification: Extra Heavy in accordance with AS/NZS 4200.1:2017