PIRMAX HRFC Panel
High Thermal Performance Insulated Fibre CementProduct Introduction
PIRMAX HRFC PANEL is a modified PIR (Polyisocyanurate) rigid thermoset insulation laminated with a 6mm fibre cement. PIRMAX HRFC PANEL consists of one side recessed or straight edge 6mm fibre cement and foil on the reverse side adhesively bonded to the PIR core.
Alternative linings, such as 9mm fibre cement, can also be used upon request.
PIRMAX HRFC PANEL is designed to achieve excellent thermal value where minimal cavity is required giving buildings continued thermal efficiency throughout their life span. PIRMAX HRFC PANEL is easy to handle and allows fast fixing to any application. Fully compliant to the Australian National Construction Code.
PIRMAX HRFC PANEL is CFC free with zero Ozone Depletion Potential (ODP), does not release Volatile Organic Compounds (VOC’s) and is manufactured in Australia.
- Complies with AS/NZS 4859.1:2018.
- Amongst the highest thermal values of rigid board insulation due to the product’s low thermal conductivity.
- Achieves a Group 1 BCA/NCC fire classification when tested to AS 5637.1 (AS/NZ 3837), compliant to the National Construction Code, NCC/BCA Volume 1; Specification C1.10.
- Not corrosive to metal over time.
- Able to custom manufacture to different sizes and facing colours.
- Fast manufacturing turnaround times.
Australian Made
PIRMAX HRFC PANEL is manufactured in Australia by an Australian owned and operated company, and guarantee the highest quality insulation material. Raw materials and chemicals are also sourced from Australian companies wherever possible. As our products are wholly Australian Made we take pride in our manufacturing to ensure a high standard of quality, service and value.
Applications
Soffit (Carpark Application), Wall Systems.
Blank one so all stay closed
Product Details
Product Name | PIRMAX - HRFC Panel “modified PIR rigid thermal insulation with fibre cement” |
Thermal Conductivity Insulation: | 20mm-35mm: 0.023 W/m.K 40mm-75mm: 0.021 W/m.K 80mm-95mm: 0.020 W/m.K |
Thermal Conductivity Fibre Cement: | 0.33 W/mK |
Emittance | E0.03 (silver foil face) |
Panel Thickness | 31mm, 36mm, 46mm, 56mm, 66mm, 76mm, 86mm, 96mm |
Panel Dimensions | 2400mm x 1200mm (2.88m2); 2700mm x 1200mm (3.24m2); 3000mm x 1200mm (3.6m2) Other dimensions available upon request. |
Edge Treatment | Fibre cement recessed edge and square edge PIR (Fibre cement also available in square edge) |
Product R Values
Nominal Thickness | Declared Product R-value at 23ºC |
---|---|
31mm | R1.06 |
36mm | R1.31 |
46mm | R1.91 |
56mm | R2.36 |
66mm | R2.86 |
76mm | R3.31 |
86mm | R4.01 |
96mm | R4.51 |
Product Testing
Complies to AS/NZ 4859.1:2018 and NCC/BCA Compliant | ||
Group Classification | AS 5637.1 | Group 1* |
Ignitability Index | AS 1530.3 | 0 Range 0-20** |
Spread of Flame Index | AS 1530.3 | 0 Range 0-10** |
Heat Evolved Index | AS 1530.3 | 0 Range 0-10** |
Smoke Developed Index | AS 1530.3 | 1 Range 0-10** |
Compressive Strength | AS 2498.3 | >125 (kPa)** |
Water Vapour Resistivity | ASTM E96 | >100 (MNs/gm) |
* Applies to compliant fibre cement facing tested to AS/NZS 3837.1
**Applies to the PIR core
Environmental
Water Use | No water used in the manufacturing process |
Processing Greenhouse gas emissions | No Greenhouse gas emissions in manufacturing process |
Ozone depleting substances | None present in finished product, zero ODP PIRMAX contains no CFC’s or HCFC’s |
Occupational Health & Safety | Not Hazardous No Formaldehyde Does not release Volatile Organic Compounds (VOC) |
Transport | Australian made & owned, not transported from overseas, minimal carbon footprint |
Energy Efficient | Long term energy savings and environmental benefits |
Specification Notes
Product Name: PIRMAX HRFC PANEL _____mm
The insulation to be installed shall be PIRMAX HRFC Panel PIR insulation laminated with fibre cement, comprised of Modified Polyisocyanurate Rigid Panel with 6mm fibre cement facing on one
side and a foil facing on the other, and an R Value of _____. Product is Australian Made, manufactured by PIRMAX Pty Ltd and shall be installed in accordance with manufacturers installation instructions.