
TradeSelect FireSark®
For use in Non-Combustible ConstructionTrade Select™ FireSark® is suitable for use in Non-Combustible construction in compliance with NCC Volume One C1.9(e)(vi) and Volume Two Part 3.7.1.1(f). Superior fire performance results from the choice of Non-Combustible fibreglass weave for the bulk of the material and naturally non-combustible aluminium.
Classified as a Water Barrier, and Class 2 Vapour Barrier. Trade Select™ FireSark® is a barrier to embers, radiant heat, moisture ingress, draughts and dust penetration.
Product Advantages
- Suitable for use in Non-Combustible construction
- Ember-proof
- Ideal for all BAL zones to FZ bushfire-prone areas
- Water and Air Barrier
- Class 2 Vapour Barrier
- 97% Reflective
Applications
Trade Select™ FireSark® is designed for use as a roof sarking and wall wrap in residential and commercial buildings in all regions of Australia. Suitable for use in Non-Combustible construction and for external wall construction in all building classes, and particularly where superior fire performance is desired. The 97% reflective foil face provides extra R-value when installed facing an air cavity.
NOTE: Water Barrier, Class 3 to 4 Vapour Permeable is required for walls in Climate Zones 6-8.
Blank one so all stay closed
Product Details
Product Name | Trade Select™ FireSark® |
Roll Size | 1350 mm x 30 m (40.5m2) |
Duty Rating | Extra Heavy |
R Values

Product Testing
NCC/BCA Compliant
Trade Select™ FireSark® complies with AS/NZS 4200.1:2017, and therefore meets all the requirements of the National Construction Code and Building Code of Australia for pliable building membranes and sarking-type materials.
Combustibility | AS 1530.1-1993 | Not deemed combustible |
Flammability Index | AS 1530.2-1993 | Low ≤ 5 |
Early Fire Hazard Indicies | AS 1530.3-1993 | 0, 0, 0, 2 |
Duty Rating | AS/NZS 4200.1:2017 | Extra Heavy |
Emmitance | AS/NZS 4201.5:1994 | Printed side: 0.90, Foil side: 0.03 |
Vapour Barrier | ASTM E96 | Class 2 Vapour Barrier |
Water Control | AS/NZS 4201.4:1994 | Water Barrier |
Air Control | ISO 6536/5-2003 | Air Barrier |
Resistance to Dry Delamination | AS/NZS 4201.1:1994 | Pass |
Resistance to Wet Delamination | AS/NZS 4201.2:1994 | Pass |
Shrinkage (Repeated wetting & drying) | AS/NZS 4201.3:1994 | 0.0% |
Trade Select™ FireSark® is suitable for use in Non-Combustible construction in compliance with NCC Volume One C1.9(e)(vi) and Volume Two Part 3.7.1.1(f). Superior fire performance results from the choice of Non-Combustible fibreglass weave for the bulk of the material and naturally non-combustible aluminium.
Trade Select™ FireSark® Offers a Triple Crown of Safety:
AS 1530.1—1994 Methods for fire tests on building materials, components and structures Part 1: Combustibility tests for materials. The fibreglass fabric and aluminium foil have achieved a result of not deemed combustible.
AS 1530.2—1993 Methods for fire tests on building materials, components and structures Part 2: Test for flammability of materials.
FireSark® achieves a flammability index of 1 or Low (≤5)
AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke release
The early fire hazard indices are:
Ignitability: 0
Spread of flame: 0
Heat evolved: 0
Smoke developed: 2
Bushfire Attack Levels
Trade Select™ FireSark® complies with AS 3959-2009 Construction of buildings in bushfire-prone areas for use in BAL – LOW to BAL – FZ building construction. Seek independent advice regarding the selection of sarking prior to installation in the BAL design.
Specification Notes
Product Name: Trade Select™ FireSark®
The insulation to be installed shall be Trade Select™ FireSark® single-sided reflective laminate and shall be installed in accordance with AS 4200.2: 2017 Pliable Building Membranes and Underlays, Part 2: Installation.
Emittance Value: 0.90, 0.03
Emittance Classification: IR Non-reflective, IR Reflective
Vapour Control Classification: Class 2 Vapour Barrier, 0.003 μg/N·s
Water Control Classification: Water Barrier
Duty: Extra Heavy in accordance with AS/NZS 4200.1:2017
